Kóax kapall – 5mm DG80X2

210 kr.

Vöruflokkar: ,
Láttu aðra vita

Lýsing

Cavel er kapalframleiðandi á Ítalíu sem að framleiðir aðeins hágæða kapla. Við bjóðum hér helstu gerðir af kapli frá þeim. Hann fæst á 100 metra rúllum. Seljum hann í metravís hér.

RG Ref. RG 59
acc. to Standard EN 50117-2-4
CONSTRUCTION DATA
Inner Conductor Ø mm 0,80
material Cu
Dielectric Ø mm 3,50
material PEG
Film Foil Laminate material APA
Braid material CuSn
Braid Optical Coverage % 65
Diameter over Braid Ø mm 3,82
Outer Sheath Ø mm 5×11
material PVC
PHYSICAL DATA
Copper Content kg/km 22,3
Cable Weight kg/km 56,2
Min bending radius x 1/n mm 25/50
Max.Tensile Strength N 90
Fire Load MJ/km 784
kWh/km 218
ELECTRICAL DATA
Impedance Ohm 75±3@200 MHz
Capacitance (@1kHz) pF/m 52 ± 2
Velocity Ratio % 85
Attenuation (at 20°C )
at 5 MHz dB/100m 2,1
at 10 MHz dB/100m 3,0
at 30 MHz dB/100m 4,4
at 50 MHz dB/100m 5,7
at 200 MHz dB/100m 11,0
at 300 MHz dB/100m 13,5
at 470 MHz dB/100m 16,8
at 862 MHz dB/100m 23,0
at 1000 MHz dB/100m 24,9
at 1750 MHz dB/100m 33,5
at 2150 MHz dB/100m 37,4
at 2400 MHz dB/100m 39,6
at 3000 MHz dB/100m 44,8
Structural return loss (SRL)
at 5 – 470 MHz dB >30
at 470 – 1000 MHz dB >28
at 1000 – 2000 MHz dB >26
at 2000 – 3000 MHz dB >22
Shield Transfer Impedance (Zt)
5 – 30 MHz mOhm/m < 9
Screening Attenuation (SA) Class A
at 30 – 1000 MHz dB >90
at 1000 – 2000 MHz dB >75
at 2000 – 3000 MHz dB >65
DC Conductor Resistance inner/outer Ohm/km 35,0 / 18,6
Loop resistance Ohm/km 53,6
Sheat Insulation voltage (spark test) kV 2,5
Maximum current (Ieff) A 4